Hertz HRD Series

Durable, compact and efficient Hertz dryers will soon become the global standard for performance. Heat-Exchanger design is unique and patented. The Mono-Block Heat-Exchangers are constructed with thick, steel tubes specially treated to resist corrosion.

Download HRD Series Brochure

MODEL Capacity* Connection Size Voltage** Refrigerant Maximum Working Pressure Maximum Ambient Temperature Maximum Inlet Temperature Included Filter and Type Dimensions (mm) Weight
m3/min cfm bar 0C 0C Length Width Height Kg
HRD 10 0.35 12 G ½” 230V/1/50 Hz R-134a 16 50 60 HGKO 45 MX+MY 423 393 567 32
HRD 20 0.58 20 G ½” 230V/1/50 Hz R-134a 16 50 60 HGKO 45 MX+MY 423 393 567 32
HRD 30 0.83 29 G ½” 230V/1/50 Hz R-134a 16 50 60 HGKO 45 MX+MY 423 393 567 32
HRD 35 1.05 37 G ½” 230V/1/50 Hz R-134a 16 50 60 HGKO 70 MX+MY 423 393 567 35
HRD 40 1.45 51 G ¾” 230V/1/50 Hz R-134a 16 50 60 HGKO 150 MX+MY 473 453 832 51
HRD 50 2.17 77 G ¾” 230V/1/50 Hz R-134a 16 50 60 HGKO 150 MX+MY 473 453 832 53
HRD 60 2.83 100 G ¾” 230V/1/50 Hz R-134a 16 50 60 HGKO 150 MX+MY 473 453 832 55
HRD 70 3.3 117 G 1 ½” 230V/1/50 Hz R-134a 16 50 60 HGKO 500 MX+MY 553 503 874 78
HRD 80 4.7 166 G 1 ½” 230V/1/50 Hz R-134a 16 50 60 HGKO 500 MX+MY 553 503 874 83
HRD 90 5.9 208 G 1 ½” 230V/1/50 Hz R-134a 16 50 60 HGKO 500 MX+MY 553 503 874 86
HRD 100 7.8 275 G 2″ 230V/1/50 Hz R-134a 16 50 60 HGKO 851 MX+MY 678 648 1157 160
HRD 110 9.8 346 G 2″ 230V/1/50 Hz R-134a 16 50 60 HGKO 1210 MX+MY 678 648 1157 165
HRD 120 13.8 487 G 2″ 230V/1/50 Hz R-134a 16 50 60 HGKO 1210 MX+MY 948 728 1370 220
HRD 130 18.3 646 G 2″ 230V/1/50 Hz R-134a 16 50 60 HGKO 1210 MX+MY 948 728 1370 230
HRD 140 21.8 770 G 3″ 400V/3/50Hz R-134a 16 50 60 HGKO 1820 MX+MY 948 798 1460 270
HRD 150 27.1 957 G 3″ 400V/3/50Hz R-134a 16 50 60 HGKO 1820 MX+MY 948 798 1460 285
HRD 160 36.7 1296 G 3″ 400V/3/50Hz R-134a 16 50 60 HGKO 2700 MX+MY 1163 778 1725 392
HRD 170 43.7 1543 G 3″ 400V/3/50Hz R-134a 16 50 60 HGKO 2700 MX+MY 1163 778 1725 410
HRD 180 52.4 1850 DN100 400V/3/50Hz R-134a 16 50 60 GKO 5850 MX+MY 1397 847 1770 492
HRD 190 61.6 2175 DN100 400V/3/50Hz R-134a 16 50 60 GKO 5850 MX+MY 1397 847 1770 520
HRD 200 80 2825 DN100 400V/3/50Hz R-134a 16 50 60 GKO 5850 MX+MY 1467 1077 1930 696
HRD 210 92 3249 DN100 400V/3/50Hz R-134a 16 50 60 GKO 5850 MX+MY 1467 1077 1930 718
HRD 220 109.7 3874 DN150 400V/3/50Hz R-134a 16 50 60 Not Included 2188 1062 1925 900
HRD 230 123.9 4375 DN150 400V/3/50Hz R-134a 16 50 60 Not Included 2188 1062 1925 925
HRD 240 141.6 5001 DN150 400V/3/50Hz R-134a 16 50 60 Not Included 2247 1200 2044 975
HRD 250 165.2 5834 DN200 400V/3/50Hz R-134a 16 50 60 Not Included 2247 1200 2044 1100
HRD 260 196.7 6946 DN200 400V/3/50Hz R-134a 16 50 60 Not Included 2550 1550 2100 1400

Easy to Access

Easy to access in to the cooling components in seconds by the help of Screw free panels and plastic handles.

Electrical wires are seperated from Refrigerant Side

No electrical wires inside the refrigerant side of the dryer. Electrical Box has an external cover which has an access from the outside of the dryer. No need to open dryer panels to go in to electrical box.

Digital Controller with a lot of economy features and alarm capabilities is standard for all 3Ph dryers

(HRD140 and up)

Compact Design

As the canopy of the dryer is designed not to leave any unused space inside, HRD series air dryers cover minimal space where they are placed.

Refrigerated Type HRD Compressed Air Dryers

3 °C pressure dew point

Very Low Pressure Drop

Designed for Tropical Conditions

Dryer easily runs at 60 °C Max. Inlet Temp. and 50 °C Ambient Temp.due to R134a refrigerant (all through the range) and oversized condense

Aluminum Heat Exchanger is Standard

Very Low Pressure Drop (100mbar)

Very Efficient (3 oC real pressure dew poin